Fat suppression: STIR vs spectral vs opposed-phase
A comparison table of three MRI fat techniques across five rows. STIR uses inversion-recovery timing (TI about 0.69 times T1 of fat), is non-specific to fat, is robust to B0 and B1 inhomogeneity, and has lower SNR. Spectral fat saturation uses a narrowband RF pulse at fat's resonance frequency plus a spoiler, is fat-specific, requires a homogeneous B0 field, and has higher SNR. Opposed-phase imaging uses gradient echo at an opposed-phase echo time so fat and water cancel only within mixed voxels; bulk fat stays bright, so it is a detection method rather than a bulk-fat suppressor.